Podsumowanie treści

Strona 1 - Series Dehumidifying Dryers

Cabinet Series Dehumidifying Dryer Chapter 1: Safety 1 Operation and Installation Manual 90,100, 150, 225 CFM Cabinet Series Dehumidifying Drye

Strona 2

Cabinet Series Dehumidifying Dryer 10 If you need to repair a large component, use appropriate handling equipment. Before you use handling equip

Strona 3 - Table of Contents

Cabinet Series Dehumidifying Dryer 11 Chapter 2: General Information 2-1 Models Covered This manual provides instructions for installing and o

Strona 4

Cabinet Series Dehumidifying Dryer 12 ; Audible/visual critical alarm. ; Fusing for blowers and heaters. ; Dirty Filter indicator for each ind

Strona 5

Cabinet Series Dehumidifying Dryer 13 2-7 What is Desiccant? Desiccant is a material which attracts and holds (absorbs) water from the air. Our d

Strona 6 - Chapter 1: Safety

Cabinet Series Dehumidifying Dryer 14 Chapter 3: Installation 3-1 Positioning Your Dryer The dehumidifying dryer system was designed to be whe

Strona 7 - Description

Cabinet Series Dehumidifying Dryer 15 3-5 Process Air Connections Between the Dryer and Drying Hopper ; Remove the cap plugs from the inlet, di

Strona 8 - 1-3 Responsibility

Cabinet Series Dehumidifying Dryer 16 Chapter 4: Controls 4-1 Control Panel Indicator Lights and Switches Rocker Switches System ON/OFF Rocker

Strona 9 - Maintenance Responsibility

Cabinet Series Dehumidifying Dryer 17 Indicator Name Description compressed air, the pressure switch opens and sends a signal to the PLC contro

Strona 10 - Reporting a Safety Defect

Cabinet Series Dehumidifying Dryer 18 Figure 2-Typical Dyer Interface Panel

Strona 11 - 2-5 Options

Cabinet Series Dehumidifying Dryer 19 4-2 Process Air Dew Point Display The Dew Point display indicates the current process air delivery moistur

Strona 12

Cabinet Series Dehumidifying Dryer 2 Performance figures stated in this manual are based on a standard atmos

Strona 13 - 2-7 What is Desiccant?

Cabinet Series Dehumidifying Dryer 20 4-5 Identifying Temperature Controller Buttons Display Button This button shifts the display to the next

Strona 14 - Chapter 3: Installation

Cabinet Series Dehumidifying Dryer 21 E5CK Operating Parameters The E5CK has several mode selections. Within each mode are numerous parameters t

Strona 15 - 3-7 Drying Hopper

Cabinet Series Dehumidifying Dryer 22 Figure 4: Display Readout for Mode Settings PVSVSVSVSVSVSVSVMenu displayLeve

Strona 16 - Chapter 4: Controls

Cabinet Series Dehumidifying Dryer 23 PLC LED Indicators The following indicators are located inside the dryer cabinet. See Figures 5, 6, and 7

Strona 17 - Indicator Name Description

Cabinet Series Dehumidifying Dryer 24 Output LED Indicators Name Description Blower On (O/0) The Blower On indicator lights when the blower en

Strona 18

Cabinet Series Dehumidifying Dryer 25 Figure 5: Typical Subpanel Layout

Strona 19

Cabinet Series Dehumidifying Dryer 26 Figure 6: Typical Cabinet Dryer Electrical Schematic, Drawing 1 \

Strona 20 - MANU STOP RMT AT SUB1

Cabinet Series Dehumidifying Dryer 27 Figure 6: Typical Cabinet Dryer Electrical Schematic, Drawing 2 222

Strona 21 - Available E5CK Modes

Cabinet Series Dehumidifying Dryer 28 4-8 Setting the Shift on Dew Point Our dehumidifying dryers shift air flow from the on-line desiccant bed

Strona 22 - 4-7 PLC Controller

Cabinet Series Dehumidifying Dryer 29 5. Use the Up and Down Arrow buttons to set the higher or lower value for the high dew point alarm. Hold

Strona 23 - Name Description

Cabinet Series Dehumidifying Dryer 3 Table of Contents CHAPTER 1: SAFETY……………………………………………...6 1-1 How to Use This Manual. ...

Strona 24

Cabinet Series Dehumidifying Dryer 30 No. Function 1 Shifts the cursor (∇) specifying a day to the right. 2 Sets or cancels (reset) a specified

Strona 25

Cabinet Series Dehumidifying Dryer 31 8. Press the WRITE key (#6) to store the correct time. 9. The time and day can be adjusted or changed whi

Strona 26

Cabinet Series Dehumidifying Dryer 32 1. Hold the COPY key (#9) for one (1) second or longer. Make sure that the mode selector switch is in RUN

Strona 27

Cabinet Series Dehumidifying Dryer 33 - Notes -

Strona 28

Cabinet Series Dehumidifying Dryer 34 Chapter 5: Operation 5-1 Pre-Startup Checks 1. Verify that the drying hopper is clean of rust-prohibitiv

Strona 29

Cabinet Series Dehumidifying Dryer 35 twenty minutes to cool down the process. The regeneration cycle of the off-line bed completes the cycle bef

Strona 30

Cabinet Series Dehumidifying Dryer 36 Chapter 6: Maintenance 6-1 Work Rules The installation, operation, and maintenance of this equipment is to

Strona 31 - Checking the Set Time

Cabinet Series Dehumidifying Dryer 37 Recommendations for Cleaning and Replacing Filters • Turn off and/or lock out electrical power to the dry

Strona 32 - Canceling the Settings

Cabinet Series Dehumidifying Dryer 38 Preventative Maintenance Checklist Dehumidifying Dryer Systems System model # Serial # Every week

Strona 33 - - Notes

Cabinet Series Dehumidifying Dryer 39 6-3 Servicing the Dew Point Monitor The accuracy of the dew point monitor on dehumidifying dryer systems

Strona 34 - Chapter 5: Operation

Cabinet Series Dehumidifying Dryer 4 4-6 Setting the Process Air Temperature ...

Strona 35

Cabinet Series Dehumidifying Dryer 40 First Aid: In case of eye contact, immediately flush eyes with plenty of water for at least 15 minutes. If

Strona 36 - Chapter 6: Maintenance

Cabinet Series Dehumidifying Dryer 41 Figure 7: Required Desiccant Amounts per Bed; Type 4X Desiccant (2 beds per unit) Dryer Large bead (Type

Strona 37

Cabinet Series Dehumidifying Dryer 42 6-7 Replacing the Regeneration Heater The dehumidifying dryers use heater elements located below each desi

Strona 38 - Dehumidifying Dryer Systems

Cabinet Series Dehumidifying Dryer 43 2. Make sure jumper setting for input type is set for thermocouple TC-PT, middle jumper. 3. Return contro

Strona 39

Cabinet Series Dehumidifying Dryer 44 Level 1 AL-2 Alarm Value 2 -1999 to 9999 EU 0 25.0 Level 1 AL-3 Alarm Value 3 -1999 to 9999 EU 0 D

Strona 40 - 6-5 Replacing Worn Desiccant

Cabinet Series Dehumidifying Dryer 45 Initialize Setup 6UE1 Control Output 1 Assignment Heat/Cool/Alarm 1/Alarm 2/Alarm 3/ LBA Heat Default Setup

Strona 41

Cabinet Series Dehumidifying Dryer 46 Option Type RE232C RS-485 Event Input Transfer Output Board Number E53-CK01 E53-CK03 E53-CKB E53-CK

Strona 42 - WARNING!

Cabinet Series Dehumidifying Dryer 47 Level 2 Cn5L input shift lower limit -999.9 to 999.9°C 0.0 Default Mode Parameter Setting range Default

Strona 43

Cabinet Series Dehumidifying Dryer 48 - Notes -

Strona 44

Cabinet Series Dehumidifying Dryer 49 Chapter 7: Troubleshooting Problem Possible cause Corrective action Dirty filter. Clean or replace filte

Strona 45 - Option Boards

Cabinet Series Dehumidifying Dryer 5 Charts and Figures 1 Dryer Air Flow Diagram 122 Typical Dryer Interface Panel 183 Typical Dryer Temperat

Strona 46

Cabinet Series Dehumidifying Dryer 50 Problem Possible cause Corrective action Airflow valve sticking or failing to shift. Check for proper o

Strona 47 - Meter to Factory Setup

Cabinet Series Dehumidifying Dryer 51 Problem Possible cause Corrective action The internal mechanism is not inserted properly into the housi

Strona 48

Cabinet Series Dehumidifying Dryer 52 CHAPTER 8: APPENDIX 8-1 Contact Information Parts Department Call toll-free 7am–5pm CST [800] 423-3183 o

Strona 49 - Chapter 7: Troubleshooting

Cabinet Series Dehumidifying Dryer 6 Chapter 1: Safety 1-1 How to Use This Manual Use this manual as a guide and reference for installing, oper

Strona 50

Cabinet Series Dehumidifying Dryer 7 Dryer Safety Tags Tag Description Tag Description Read Operation & Installation Manual High Voltage Ins

Strona 51

Cabinet Series Dehumidifying Dryer 8 We have long recognized the importance of safety and have designed and manufactured our equipment with opera

Strona 52 - CHAPTER 8: APPENDIX

Cabinet Series Dehumidifying Dryer 9  NEVER place your hands or any part of your body in any dangerous location.  NEVER operate, service, or

Komentarze do niniejszej Instrukcji